Dell E05S001 Server User Manual


 
About Your System 33
E2010 Memory not
detected.
Inspect
DIMMs.
No memory detected in the
system.
Install memory or reseat
the memory modules. See
"Installing Memory
Modules" on page 97 or
"Troubleshooting System
Memory" on page 159.
E2011 Memory
configuration
failure.
Check DIMMs.
Memory detected, but is not
configurable. Error detected
during memory
configuration.
See "Troubleshooting
System Memory" on
page 159.
E2012 Memory
configured
but unusable.
Check DIMMs.
Memory configured, but is
unusable.
See "Troubleshooting
System Memory" on
page 159.
E2013 BIOS unable
to shadow
memory. Check
DIMMs.
The system BIOS failed to
copy its flash image into
memory.
See "Troubleshooting
System Memory" on
page 159.
E2014 CMOS RAM
failure.
Power cycle
AC.
CMOS failure. CMOS RAM
not functioning properly.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help" on
page 185.
E2015 DMA
Controller
failure.
Power cycle
AC.
DMA controller failure. Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help" on
page 185.
E2016 Interrupt
Controller
failure.
Power cycle
AC.
Interrupt controller failure. Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help" on
page 185.
Code Text Causes Corrective Actions
book.book Page 33 Wednesday, February 17, 2010 6:17 PM