Error Code Message Information
Action Check presence, reinstall or reconnect, then reattempt the
update. If the issue persists, see Getting Help.
HWC4015
Message Link Tuning error detected.
Details CMC has old firmware. After updating the firmware the CMC
will recognize the device.
Action Update the CMC firmware. If the issue persists, see Getting
Help.
HWC5001
Message <name> is offline.
Action If unexpected, check presence, then reinstall or reconnect.
HWC5002
Message A fabric mismatch detected on <name>.
Details The fabric type for the IOM and mezzanine cards must
match.
Action Check chassis fabric type in CMC GUI and compare to the
type of IOM or mezzanine card.
HWC5004
Message A link tuning failure detected on <name>.
Details CMC has old firmware. After updating the firmware the CMC
will recognize the device.
Action Update the CMC firmware. If the issue persists, see Getting
Help.
HWC5006
Message A failure is detected on <name>.
Action If the issue persists, see Getting Help.
HWC5008
Message Console is not available for the <name>.
Action If the issue persists, see Getting Help.
HWC5010
Message <name> cannot detect any hosts.
Action If the issue persists, see Getting Help.
HWC5014
Message <name> is not functional and is powered off.
Action If the issue persists, see Getting Help.
102