Dell M820 Server User Manual


 
Error Code Message Information
Details System hardware detected an over voltage or under voltage
condition.
If multiple voltage exceptions occur consecutively the
system may power down in fail-safe mode.
Action
1. Review system logs for power supply exceptions.
2. Re-seat the mezzanine card.
3. If the issue persists, see Getting Help.
VLT0232
Message The mezzanine card <number> <name> voltage is greater
than the upper warning threshold.
Details System hardware detected an over voltage or under voltage
condition.
If multiple voltage exceptions occur consecutively the
system may power down in fail-safe mode.
Action
1. Review system logs for power supply exceptions.
2. Re-seat the mezzanine card.
3. If the issue persists, see Getting Help.
VLT0233
Message The mezzanine card <number> <name> voltage is greater
than the upper critical threshold.
Details System hardware detected an over voltage or under voltage
condition.
If multiple voltage exceptions occur consecutively the
system may power down in fail-safe mode.
Action
1. Review system logs for power supply exceptions.
2. Re-seat the mezzanine card.
3. If the issue persists, see Getting Help.
VLT0234
Message The mezzanine card <number> <name> voltage is outside of
range.
Details System hardware detected an over voltage or under voltage
condition.
If multiple voltage exceptions occur consecutively the
system may power down in fail-safe mode.
Action
1. Review system logs for power supply exceptions.
153