Dell M820 Server User Manual


 
Error Code Message Information
VLT0203
Message The system board <name> voltage is greater than the upper
critical threshold.
LCD Message System board voltage is outside of range.
Details System hardware detected an over voltage or under voltage
condition.
If multiple voltage exceptions occur consecutively the
system may power down in fail-safe mode.
Action
1. Review system logs for power supply exceptions.
2. Re-configure the system to minimum configuration,
inspect and reinstall system cables.
3. If the issue persists, see Getting Help.
VLT0204
Message The system board <name> voltage is outside of the allowable
range.
LCD Message System board voltage is outside of range.
Details System hardware detected an over voltage or under voltage
condition.
If multiple voltage exceptions occur consecutively the
system may power down in fail-safe mode.
Action
1. Review system logs for power supply exceptions.
2. Re-configure the system to minimum configuration,
inspect and reinstall system cables.
3. If the issue persists, see Getting Help.
VLT0206
Message The memory module <number> <name> voltage is less than
the lower warning threshold.
LCD Message Memory module <number> <name> voltage is outside of
range.
Details System hardware detected an over voltage or under voltage
condition.
If multiple voltage exceptions occur consecutively the
system may power down in fail-safe mode.
Action
1. Review system logs for power supply exceptions.
2. Re-configure the system to minimum configuration,
inspect and reinstall system cables.
145