Dell M820 Server User Manual


 
Error Code Message Information
Details The <name> battery is either missing, bad, or unable to
charge due to thermal issues.
Action Check system fans. Replace the <name> battery.
BAT0019
Message The <name> battery is absent.
LCD Message The <name> battery is absent. Check battery.
Details The failed or missing <name> battery may reduce system
performance.
Action Check system fans. Replace the <name> battery.
CBL0006
Message Multiple storage controllers are incorrectly connected to the
same backplane <Bay ID>.
Details Unsupported backplane configuration.
Action Check backplane configuration. Reconnect cable. If the issue
persists, see Getting Help.
CPU0000
Message CPU <number> has an internal error (IERR).
LCD Message CPU <number> has an internal error (IERR).
Details System event log and OS logs may indicate that the
exception is external to the processor.
Action Review System Event Log and Operating System Logs. If the
issue persists, see Getting Help.
CPU0001
Message CPU <number> has a thermal trip (over-temperature) event.
LCD Message CPU <number> has a thermal trip. Check CPU heat sink.
Details The processor temperature increased beyond the
operational range.
Action Review logs for fan failures, replace failed fans. If no fan
failures are detected, check inlet temperature (if available)
and reinstall processor heat-sink.
CPU0002
Message CPU <number> has failed the built-in self-test (BIST).
Action
1. Turn system off and remove input power for one
minute. Reapply input power and turn system on.
2. Make sure the processor is seated correctly.
3. If the issue persists, see Getting Help.