Error Code Message Information
LCD Message CPU <number> voltage regulator module incorrectly
configured. Check configuration.
Details System performance may be degraded or the system may
fail to operate.
Action Review this manual for proper configuration and installation
procedures.
CPU0816
Message CPU <number> voltage regulator module is absent.
LCD Message CPU <number> voltage regulator module absent. Check
module.
Details System performance may be degraded or the system may
fail to operate.
Action If removal was unintended, check presence and reinstall.
HWC1001
Message The <name> is absent.
LCD Message The <name> is absent. Check hardware.
Details The absent device may be necessary for proper operation.
System functionality may be degraded.
Action Reinstall or reconnect the hardware.
HWC1002
Message The <name> is disabled.
Action If device disabled unexpectedly, re-enable device.
HWC1005
Message The storage adapter is absent.
LCD Message The storage adapter is absent. Check hardware.
Details The storage adapter may be necessary for proper operation.
System functionality may be degraded.
Action Install storage adapter.
HWC1006
Message The storage adapter is disabled.
Action If adapter disabled unexpectedly, re-enable the storage
adapter.
HWC1009
Message The backplane is absent.
LCD Message The backplane is absent. Check hardware.
99