Dell M820 Server User Manual


 
Error Code Message Information
Action Check the system operating environment and review event
log for fan failures.
TMP0100
Message Disk drive bay temperature is less than the lower warning
threshold.
Details Ambient air temperature is too cool.
Action Check the system operating environment.
TMP0104
Message Disk drive bay temperature is less than the lower critical
threshold.
LCD Message Disk drive bay temperature is outside of range. Check Fans.
Details Ambient air temperature is too cool.
Action Check the system operating environment.
TMP0126
Message Disk drive bay temperature is greater than the upper warning
threshold.
LCD Message Disk drive bay temperature is outside of range. Check Fans.
Details Ambient air temperature is too warm or one or more fans
may have failed.
Action Check the system operating environment and review event
log for fan failures.
TMP0128
Message Disk drive bay temperature is outside of the allowable range.
LCD Message Disk drive bay temperature is outside of range. Check Fans.
Details Ambient air temperature is too warm or cool.
Action Check the system operating environment and review event
log for fan failures.
TMP0130
Message The control panel temperature is less than the lower warning
threshold.
LCD Message Control panel temperature is outside of range.
Details Ambient air temperature is too cool.
Action Check the system operating environment.
TMP0132
Message The control panel temperature is greater than the upper
warning threshold.
141