Error Code Message Information
CPU0803
Message The power input for CPU <number> voltage regulator
module is lost.
LCD Message Lost power input for CPU <number>voltage regulator
module. Re-seat module.
Details System performance may be degraded or the system may
fail to operate.
Action
1. Turn system off and remove input power for one
minute.
2. Reapply input power and turn system on.
3. Ensure the processor is seated correctly.
4. If the issue persists, see Getting Help.
CPU0804
Message The power input for CPU <number> voltage regulator
module is outside of range.
LCD Message The power input for CPU <number> voltage regulator
module is outside of range. Re-seat module.
Details System performance may be degraded or the system may
fail to operate.
Action
1. Turn system off and remove input power for one
minute.
2. Reapply input power and turn system on.
3. Ensure the processor is seated correctly.
4. If the issue persists, see Getting Help.
CPU0805
Message The power input for CPU <number> voltage regulator
module is outside of range, but it is attached to the system.
Details System performance may be degraded or the system may
fail to operate.
Action
1. Turn system off and remove input power for one
minute.
2. Reapply input power and turn system on.
3. Ensure the processor is seated correctly.
4. If the issue persists, see Getting Help.
CPU0806
Message CPU <number> voltage regulator module is incorrectly
configured.
98