Dell M820 Server User Manual


 
Error Code Message Information
PCI2002
Message A fatal IO error detected on a component at slot <number>.
LCD Message Fatal IO error on slot <number>.
Details System performance may be degraded, or system may fail to
operate.
Action Cycle input power, update component drivers, remove and
reinstall the device.
PCI3000
Message Device option ROM on embedded NIC failed to support Link
Tuning or FlexAddress.
Details Either the BIOS, BMC/iDRAC, or LOM firmware is out of date
and does not support FlexAddress.
Action Update BIOS, BMC/iDRAC, and LOM firmware. If the issue
persists, see Getting Help.
PCI3002
Message Failed to program virtual MAC address on a component at
bus <bus>device<device>function <func>.
Details Either the BIOS, BMC/iDRAC, LOM, or NIC firmware is out of
date and does not support FlexAddress.
Action Update BIOS, BMC/iDRAC, LOM, and mezzanine card
firmware. If the issue persists, see Getting Help.
PCI3004
Message Device option ROM on mezzanine card <number> failed to
support Link Tuning or FlexAddress.
Details Either the BIOS, BMC/iDRAC, or mezzanine card firmware is
out of date and does not support FlexAddress.
Action Update BIOS, BMC/iDRAC, and mezzanine card firmware. If
the issue persists, see Getting Help.
PCI3006
Message Failed to get Link Tuning or FlexAddress data from iDRAC.
Details Either the BIOS or BMC/iDRAC firmware is out of date and
does not support FlexAddress.
Action Update BIOS, and BMC/iDRAC firmware. If the issue persists,
see Getting Help.
PCI3008
Message A non-fatal PCIe error detected on a component at bus
<bus>device<device>function <func>.
Details System performance may be degraded.
115