Dell M820 Server User Manual


 
Error Code Message Information
LCD Message Control panel temperature is outside of range.
Details Ambient air temperature is too warm or one or more fans
may have failed.
Action Check the system operating environment and review event
log for fan failures.
TMP0134
Message The control panel temperature is outside of the allowable
range.
LCD Message Control panel temperature is outside of range.
Details Ambient air temperature is too warm or cool.
Action Check the system operating environment and review event
log for fan failures.
VLT0100
Message Processor module <name> voltage is less than the lower
warning threshold.
LCD Message Processor module <name> voltage is outside of range.
Details System hardware detected an over voltage or under voltage
condition.
If multiple voltage exceptions occur consecutively the
system may power down in fail-safe mode.
Action
1. Review system logs for power supply exceptions.
2. Remove the processor module. Inspect processor
socket for bent pins.
3. If the issue persists, see Getting Help.
VLT0101
Message Processor module <name> voltage is less than the lower
critical threshold.
LCD Message Processor module <name> voltage is outside of range.
Details System hardware detected an over voltage or under voltage
condition.
If multiple voltage exceptions occur consecutively the
system may power down in fail-safe mode.
Action
1. Review system logs for power supply exceptions.
2. Remove the processor module. Inspect processor
socket for bent pins.
3. If the issue persists, see Getting Help.
142