Error Code Message Information
Action If unintended, verify drive installation. Remove and re-seat
the indicated disk. If the issue persists, see Getting Help.
PDR1001
Message Fault detected on drive <number> in disk drive bay <bay>.
LCD Message Fault detected on drive <number> in disk drive bay <bay>.
Check drive.
Details The controller detected a failure on the disk and has taken
the disk offline.
Action Re-seat the failed drive. If the issue persists, see Getting
Help.
PDR1002
Message A predictive failure detected on drive <number> in disk drive
bay<bay>.
Details The controller received a SMART error from the drive. The
drive is operational but needs replacement.
Action The drive will need replacement at the next service window.
PDR1016
Message Drive <number> is removed from disk drive bay <bay>.
LCD Message Drive <number> removed from disk drive bay <bay>. Check
drive.
Details The controller detected that the drive was removed.
Action Verify drive installation. Re-seat the failed drive. If the issue
persists, see Getting Help.
PDR1024
Message Drive mismatch detected for drive <number> in disk drive
bay <bay>.
LCD Message Drive mismatch detected for drive <number> in bay <bay>.
Install correct drive type.
Details The installed disk does not meet the array requirements, for
example a SATA disk may not operate in an array containing
SAS drives.
Action Verify that the disk meets the array requirements.
PST0128
Message No memory is detected.
LCD Message No memory is detected. Inspect memory devices.
Details System BIOS was unable to detect memory in the system .
117