232 Management: Installing Array Components
Installing the Backplane
1
Align the holes on the backplane with the holes on the array.
2
Tighten the captive screw to secure the backplane to the chassis.
See Figure 16-16 for PowerVault MD3600i or Figure 16-17 for
PowerVault MD3620i.
3
Replace the screws that secure the backplane to the chassis.
See Figure 16-16 for PowerVault MD3600i or Figure 16-17 for
PowerVault MD3620i.
4
Align the slots on the RAID controller module /power supply cage with the
tabs on the chassis. See Figure 16-15.
5
Push the RAID controller module /power supply cage toward the front of
the array.
6
Replace the screws that secure the RAID controller module /power supply
cage to the chassis.
7
Replace the control panel. See "Installing the Control Panel" on page 228.
8
Replace the power supply/cooling fan modules. See "Installing a Power
Supply/Cooling Fan Module" on page 226.
9
Replace the hard drives. See "Installing a Hard Drive" on page 214.
10
Connect all the cables to the array.
11
Turn on the array and the host server.
book.book Page 232 Thursday, December 9, 2010 3:20 PM