D-Link DGS-3700 Switch User Manual


 
DGS-3700-12/DGS-3700-12G Series Layer 2 Gigabit Ethernet Switch User Manual
119
LLDP Management Address List
This window is used to find the LLDP management address information on the Switch.
To view this window, click L2 Features > LLDP > LLDP Management Address List as shown below:
Figure 3 - 68 LLDP Management Address List window
The following parameters can be set:
Parameter Description
Address
Use the drop down menu to select either the IPv4 or IPv6 Address. Enter the management ip
address or the ip address of the entity you wish to advertise to. IPv4/IPv6 is a management IP so
the IP information will be sent with the frame when the mgt_addr config is enabled.
Click Find to implement changes made.
LLDP Basic TLVs Settings
This window is used to enable the settings for the Basic TLVs Settings. An active LLDP port on the Switch always
includes mandatory data in its outbound advertisements. There are four optional data types that can be configured for
an individual port or group of ports to exclude one or more of these data types from outbound LLDP advertisements.
The mandatory data type includes four basic types of information (end of LLDPDU TLV, chassis ID TLV, port ID TLV,
and Time to Live TLV). The mandatory data types cannot be disabled. There are also four data types which can be
optionally selected. These include Port Description, System Name, System Description and System Capability.
To view this window, click L2 Features > LLDP > LLDP Basic TLVs Settings as shown below:
Figure 3 - 69 LLDP Basic TLVs Settings window
Use the drop-down menus to enable or disable the settings for the Basic TLVs Settings. Click Apply to implement
changes made.
The following parameters can be set:
Parameter Description
From Port /To Port
Use the pull-down menu to select a range of ports to be configured.