Extron electronic FPC 5000 Switch User Manual


 
Matrix 12800 Operation, cont’d
FPC 5000 Front Panel Controller • Matrix 12800 Operation3-4
Starting Up the Controller and Logging In and Out
Use the FPC to control the matrix as follows:
1. Ensure that all BMEs that are part of the system have been connected to each
other and their BME numbers have been set correctly (refer to the Matrix
12800 Wideband, Sync, or Audio Switchers User’s Manual, part #68-556-01).
2. If necessary, on the rear of the FPC, toggle the Power switch to the on (
)
position. After approximately 2 minutes, the LCD touch panel displays the
FPC startup screen (figure 3-4). Observe the message **NOT Logged On** in
the upper right corner of the blue field.
Figure 3-4 — Startup screen
The FPC 5000 LCD has an optional screen saver function that blanks the
screen after 5 minutes. Touch on the screen to wake up the controller. See
Miscellaneous screen, in this chapter, to disable the screen saver.
3. Touch the Log On button.
The IP Connection screen appears (figure 3-5).
Figure 3-5 — Address and password entry
4. Decide whether you need to edit the FPC 5000’s IP Address and Subnet Mask
fields (see the guidelines below). If you need to edit the fields, proceed to
step 5. If you do not need to need to edit the fields, proceed to step 6.