Extron electronic FPC 5000 Switch User Manual


 
3-21FPC 5000 Front Panel Controller • Matrix 12800 Operation
DSVP screen
You can monitor each RGBHV and RGBS input to see if active sync signal(s) are
present on the DSVP™ (Digital Sync Validation Processing™) screen (figure 3-12).
Access the DSVP screen by touching the blue User > amber DSVP buttons.
Figure 3-12 — DSVP screen
Where an input has active sync present, the DSVP screen reports a snapshot in time
of the frequencies in the horizontal and vertical frequency fields. Where no active
sync signals are present, the DSVP screen shows —— in the horizontal and vertical
frequency fields. Inputs that have not been virtualized (refer to the Matrix 12800
Wideband, Sync, or Audio Switchers User’s Manual, part #68-556-01) or for which there
is not a sync BME are marked by “n/a” in the horizontal and vertical frequency
fields
. Update the DSVP screen to display fresh frequency readings by
touching the green Update button.