Control ports
r RS-232 remote — A 3-pole, 3.5 mm captive screw connector for connection of a host
computer or a controller using SIS or Windows-based control software.
Ground ( _ )
Receive (Rx)
Transmit (Tx)
Bidirectional
RS-232
Device
Ground ( _ )
Receive (Rx)
Transmit (Tx)
RxTx G
Do not tin
the wires!
Figure 10. RS-232 Captive Screw Connector Wiring
See Remote Control Port (RS-232) on page22 for additional wiring details.
s Reset button — Recessed button to return the MPS602 to factory default settings.
c USB Configuration Port (front panel) — (see Front Panel Operation on page12)
One mini type-B female USB jack for configuration of the switcher and firmware
upgrades (see Updating Firmware on page36).
Twisted Pair Recommendations
Supported Cables
The MPS602 is compatible with CAT 5e, 6, 6a, and 7 shielded twisted pair (F/UTP, SF/UTP,
and S/FTP) and unshielded twisted pair (U/UTP) cable.
ATTENTION:
Do not use Extron UTP23SF-4 Enhanced Skew-Free AV UTP cable or STP201
cable to link the scaler with DTP transmitters or receivers.
Do not connect these devices to a computer or telecommunications network.
DTP remote power is intended for indoor use only. No part of the network that
uses DTP remote power should be routed outdoors.
Cable Recommendations
Extron recommends using the following practices to achieve full transmission distances and
reduce transmission errors.
Use the following Extron XTP DTP 24 SF/UTP cables and connectors for the best
performance:
XTP DTP 24/1000 Non-Plenum 1000’ (305 m) spool 22-236-03
XTP DTP 24P/1000 Plenum 1000’ (305 m) spool 22-235-03
XTP DTP 24 Plug Package of 10 101-005-02
If not using XTP DTP 24 cable, at a minimum, Extron recommends 24 AWG, solid
conductor, STP cable with a minimum bandwidth of 400 MHz.
Terminate cables with shielded connectors to the TIA/EIA-T568B standard.
Limit the use of more than two pass-through points, which may include patch points,
punch down connectors, couplers, and power injectors. If these pass-through points
are required, use CAT 6 or 6a shielded couplers and punch down connectors.
NOTE: When using CAT 5e or CAT 6 cable in bundles or conduits:
Do not exceed 40% fill capacity in conduits.
Do not comb the cable for the first 20 m, where cables are straightened, aligned,
and secured in tight bundles.
Loosely place cables and limit the use of tie wraps or hook and loop fasteners.
Separate twisted pair cables from AC power cables.
MPS602 • Installation 9