Hand Held Products 4410 Scanner User Manual


 
3 - 38
2D Matrix Symbologies
MaxiCode
< Default All MaxiCode Settings >
MaxiCode
Message Length
The message length selection is used to set the valid reading length of the bar
code. If the data length of the scanned bar code doesn’t match the valid reading
length, the scanner will not read the symbol. You may wish to set the same value
for minimum and maximum length to force the scanner to read fixed length bar
code data. This helps reduce the chances of a misread.
EXAMPLE:Decode only those bar codes with a count of 9-20 characters.
Min. length = 09 Max. length = 20
EXAMPLE:Decode only those bar codes with a count of 15 characters.
Min. length = 15 Max. length = 15
The desired message length and
Save
must be input after reading this
programming symbol. Refer to the Programming Chart (inside back cover).
* Off
On
Maximum
Message Length
Minimum
Message Length