HP (Hewlett-Packard) 8212ZL Switch User Manual


 
143
Enhancements
Release K.13.41 Enhancements
Figure 35. Example of the Logging Command with a Priority Description
Note
A notification is sent to the SNMP agent if there are any changes to the syslog parameters either
through the CLI or with SNMP.
Operating Notes
Duplicate IP addresses are not stored in the list of syslog servers.
If the default severity value is in effect, all messages that have severities greater than
the default value are passed to syslog. For example, if the default severity is “debug”, all
messages that have severities greater than debug are passed to syslog.
There is a limit of six syslog servers. All syslog servers are sent the same messages using
the same filter parameters.
An error is generated for an attempt to add more than six syslog servers.
Release K.13.41 Enhancements
No enhancements; Bug fixes only. (Not a public release)
Release K.13.42 Enhancements
No enhancements; Bug fixes only. (Never released)
Release K.13.43 Enhancements
Release K.13.43 includes the following enhancements (Not a public release):
Enhancement (PR_0000003557) — The ability to enable/disable the USB port via CLI and
SNMP was added. Note that after being disabled and subsequently re-enabled, the USB port
may not function consistently with the PCM USB Autorun features until the switch has been
reloaded.
ProCurve(config)# logging priority-descr severe-pri