Software Fixes in Release K.11.12 - K.13.49
Release K.13.24
Authentication (PR_0000007209) — A PC behind a tandem IP phone is not able to
authenticate.
Release K.13.24
The following problems were resolved in release K.13.24 (not a public release).
OSPF (PR_0000006183a) — OSPF ECMP may drop up to 50% of the traffic destined for
its next hop. This fix adds to that implemented in K.13.22 via the same PR.
Crash (PR_0000003949) — Implementation of OSPF ECMP route changes may cause the
switch to crash with a message similar to the following.
Software exception at exception.c:501 -- in 'eRouteCtrl', task ID =
0x83da3f0 -> Memory system error at 0x7bd9540 - memPartFree
802.1X (PR_ 0000007259) — Configuring 802.1X without activating it does not function
as expected, resulting in blocking of the port.
Release K.13.25
The following problems were resolved in release K.13.25.
SSH (PR_0000002934) — Copying the client's public SSH keys from the switch fails with
the following error.
Couldn't read from remote file "/ssh/mgr_keys/authorized_keys
Crash (PR_0000004023) — Repeated PCM configuration scans may cause the switch to
crash with a message similar to the following.
PPC Data Storage (Bus Error) exception vector 0x300: Stack
Frame=0x07af44c0
HW Addr=0x6520463a IP=0x00965a88 Task='tSsh0' Task ID=0x7af4810fp:
0x013d97cc sp:0
Management Module (PR_0000005902) — The management module may become
unresponsive, resulting in loss of Telnet, Web Management, and console access functionality
of the switch.
802.1X Authentication (PR_0000002695) — When an 802.1X enabled port belongs to a
VLAN that is jumbo enabled, the Access-Request will specify a value of Framed-MTU of 9182
bytes. This allows the RADIUS server to reply with a large fragment which the switch does
not process, causing the authentication to fail. This is an additional fix for the issue described
in K.13.17 via PR_1000779048.