Software Fixes in Release K.11.12 - K.13.49
Release K.11.40
Software Exception at rt_table.c.758 -- in 'eRouteCtrl', task ID =
0x8a d6b30 -> Routing Task: Route Destinations exceeded
Release K.11.40
The following problems were resolved in release K.11.40 (not a general release)
CLI (PR_1000353548) — Use of the command show span incorrectly displays an error,
"STP version was changed. To activate the change you must save the
configuration to flash and reboot the device."
Crash (PR_1000352922) — The switch may crash with a message similar to
mstp_ptx_sm.c:118 -- in 'mMstpCtrl', task ID = 0x8899e70 -> ASSERT:
failed
Enhancement (PR_1000346164) — RSTP/MSTP BPDU Protection: When this feature is
enabled on a port, the switch will disable (drop the link) a port that receives a spanning tree
BPDU, log a message, and optionally, send an SNMP TRAP.
Release K.11.41
The following problems were resolved in release K.11.41
Enhancement (PR_1000344652) — Added support for Unidirectional Fiber Break
Detection.
Hang (PR_1000346328) — Switch hangs during initialization, switch may fail to boot.
RMON alarms/events configuration files corrupted.
MDI/MDI-X (PR_1000354050) — Forced MDI and MDIX modes were reversed on the
3500yl - forced MDI was transmitting out pins 3 and 6 instead of 1 and 2, and vice versa.
Port Monitoring (PR_1000354067) — The CLI does not allow users to mirror mesh ports,
resulting in "Error setting value monitor for port <n>".
SSH (PR_1000350999) — The SSH login prompts user to "press any key to continue" twice
before providing a prompt.
Web-UI (PR_1000354104) — The Web-UI limited the size of the "Common Name" field in
the SSL configuration tab to 16 characters
Release K.11.43
Version K.11.42 was never released.