HP (Hewlett-Packard) 8212ZL Switch User Manual


 
184
Software Fixes in Release K.11.12 - K.13.49
Release K.13.04
Enhancement (PR_ 0000000081) The CLI clear module command allows you to remove
module configuration information from the configuration file. For more information, see
“Release K.13.04 Enhancements” on page 76.
Enhancement (PR_ 0000000082) The CLI track interface command allows you to
configure tracking for a port or list of ports, or a trunk or list of trunks. For more information,
see “Release K.13.04 Enhancements” on page 76.
Enhancement (PR_ 0000000084) — DHCP Option 66 provides a way to automatically
download and initially boot from a configuration that is different from the factory-shipped
configuration. For more information, see “Release K.13.04 Enhancements” on page 76.
Enhancement (PR_ 0000000085) The DHCP relay address configuration enhancement
provides a way to configure a gateway address for the DHCP relay agent to use for DHCP
requests, rather than the DHCP relay agent automatically assigning the lowest-numbered IP
address. For more information, see “Release K.13.04 Enhancements” on page 76.
Enhancement (PR_ 0000000086) This enhancement allows rate-limiting of inbound
broadcast and multicast traffic on the switch. For more information, see “Release K.13.04
Enhancements” on page 76.
Enhancement (PR_ 0000000087) This enhancement enables a Telnet client to use the
hostname in command input. For more information, see “Release K.13.04 Enhancements”
on page 76.
Enhancement (PR_ 0000000089) The CLI show modules command displays additional
component information for system support modules and mini-GBICS. For more information,
see “Release K.13.04 Enhancements” on page 76.
Enhancement (PR_ 0000000101) This enhancement adds a vrrp option to the debug
command. For more information, see “Release K.13.04 Enhancements” on page 76.
Enhancement (PR_ 0000000420) This enhancement provides the show tech option for
customizing copy tftp output. For more information, see “Release K.13.04 Enhancements” on
page 76.
'show tech' (PR_0000000635) The show tech CLI command will cause an "Invalid
input: power" error message to be displayed in the ProCurve Switch 6200yl-24G-mGBIC.
CLI (PR_0000000358) The output from the show modules CLI command shows the
module serial number as being all zeros, or fails to show any output at all for that value.
CLI/sFlow (PR_0000000360) The switch administrator is unable to configure sFlow
for ports on modules that have not been inserted yet into the switch.