HP (Hewlett-Packard) AA-RW20A-TE Switch User Manual


 
94 Managing ports
Monitoring port status
The faceplate display provides the following port related information:
Port type
Port operational state
Port speed
Port media
To display port number and status information for a port, position the cursor over a port on the faceplate
display. The status information changes depending on the View menu option selected.
Displaying port types
To display port type status, from the faceplate display, select View > View Port Types. Table 18 lists the
possible port types and their meanings.
Displaying port operational states
To display the operational state on each port in the faceplate display, select View > View Port States.
Table 19 lists the possible operational states and their meanings. The port operational state refers to actual
port state and not the administrative state you may have assigned.
Table 18 Port types
State Description
F_Port Fabric port (point-to-point) — supports a single public device (N_Port)
FL_Port Fabric loop port — self discovers a single device (N_Port) or a loop of up to
32 public devices (NL_Port). FL_Port is the default port type for internal ports
G_Port Generic port — self discovers as an F_Port or an E_Port
GL_Port Generic loop port — self discovers as an F_Port, FL_Port, or an E_Port.
GL_Port is the default port type for external ports. A single device on a
public loop will attempt to configure as an F_Port first, then if that fails, as
an FL_Port.
E_Port Expansion port — the mode that a G_Port or GL_Port is in when attached
by an ISL (inter-switch link) to another FC switch
Table 19 Port operational states
State Description
On Online — port is active and ready to send data
Ia Inactive — port operational state is offline, but administrative state is
online
Iso Isolated — E_Port has lost its connection. Refer to ”Port Information data
window” on page 98 for information about why the E_Port has isolated.
Off Offline — port is active, can receive signal, but cannot accept a device
login
Dia Diagnostics — port is in diagnostics mode in preparation for testing
Dn Down — the port is disabled, power is removed from the lasers, and can’t
be logged in