Manual sensor test
Use this diagnostic test to manually test the product sensors and switches. Each sensor is represented by
a letter and number on the control panel display.
1.
Press the Home
button.
2. Open the following menus:
●
Administration
●
Troubleshooting
●
Diagnostic Tests
3. Press the Down arrow
button to highlight the Manual Sensor Test item, and then press the
OK button.
To exit this diagnostic, press the Stop key, and then select Exit Troubleshooting.
Menus cannot be opened during this test, so the OK button serves the same function as the Stop
button.
Table 3-7 Manual sensor diagnostic tests
Sensor or switch name Sensor or switch number
Front door switch SW1
Registration SR8
Fuser loop 1 SR14
Fuser loop 2 SR15
Fuser pressure release SR7
Fuser output SR5
Duplexer refeed SR22
Developer alienation SR11
ITB alienation SR17
Output bin full SR6
260 Chapter 3 Solve problems ENWW