HP (Hewlett-Packard) HP 83236B PCS Interface Network Router User Manual


 
19
Chapter 1, Getting Started
Step 3: Configure the Software
Scroll to and select TX Measurement Path Loss. Enter the loss (through cables, couplers, and attenuators)
between your base station’s transmitter test port and the RF IN/OUT port of the PCS Interface.
5
Configuration Information Menu
Enter the value into the highlighted
field. The Software will compen-
sate for cable loss, improving
measurement accuracy.
Scroll to and select RX Measurement Path Loss. Enter the loss of the RF cable (include loss through split-
ters, and so forth) between your base station’s receiver test port and the RF IN/OUT port of the PCS Interface.
6
Configuration Information Menu
Return to Main Menu
Base Station Channel . . . . . . . . . 220
Base Station PN Offset . . . . . . . . 16
Base Station Reference Freq. . . 19.6608 MHz
Base Station Reference To . . . . SYNTH REF IN
Base Station Power Out . . . . . . . 1.00000 Watt(s)
TX Measurement Path Loss . . . . 0.5 dB
RX Measurement Path Loss . . . . 4.0 dB
Connection Drawing Menu
PCS Band = North American Band
Beep = Off
Save Info To Memory
Load Info From Memory
Enter the value into the highlighted
field. The Software will compen-
sate for cable loss, improving
measurement accuracy.
Return to Main Menu
Base Station Channel . . . . . . . . . 220
Base Station PN Offset . . . . . . . . 16
Base Station Reference Freq. . . 19.6608 MHz
Base Station Reference To . . . . SYNTH REF IN
Base Station Power Out . . . . . . . 1.00000 Watt(s)
TX Measurement Path Loss . . . . 0.5 dB
RX Measurement Path Loss . . . . 4.0 dB
Connection Drawing Menu
PCS Band = North American Band
Beep = Off
Save Info To Memory
Load Info From Memory
Scroll to and select your band of interest.
See "Selecting a PCS Band" on page 51.
Scroll to and select PCS Band.
7 8
Configuration Information Menu
Return to Main Menu
Base Station Channel . . . . . . . . . 220
Base Station PN Offset . . . . . . . . 16
Base Station Reference Freq. . . 19.6608 MHz
Base Station Reference To . . . . SYNTH REF IN
Base Station Power Out . . . . . . . 1.00000 Watt(s)
TX Measurement Path Loss . . . . 0.5 dB
RX Measurement Path Loss . . . . 4.0 dB
Connection Drawing Menu
PCS Band = North American Band
Beep = Off
Save Info To Memory
Load Info From Memory
PCS Band Selection Menu
North American Band
Korean Band Proposal 0
Korean Band Proposal 1