HP (Hewlett-Packard) NS-series Network Card User Manual


 
Disk Drives: Monitoring and Recovery
HP Integrity NonStop NS-Series Operations Guide—529869-005
10-6
Monitoring Disk Drives With SCF
2. Get information about a disk with SCF STATUS DISK, DETAIL. For example:
-> STATUS DISK $DATA09, DETAIL
The output from this example shows that $DATA09 is in the STOPPED state,
HARDDOWN substate.
3. See Recovery Operations for a Down Disk or Down Disk Path on page 10-14.
Examples
To display the status of the disk $DATA01:
-> STATUS $DATA01
To display the status of the mirror disk of the volume $DATA02:
-> STATUS $DATA02-M
STORAGE - Detailed Status DISK \SHARK.$DATA09
Disk Path Information:
LDev Path Status State Substate Primary Backup
PID PID
92 PRIMARY INACTIVE STOPPED HARDDOWN 2,266 3,266
92 BACKUP INACTIVE STOPPED HARDDOWN 2,266 3,266
92 MIRROR INACTIVE STOPPED HARDDOWN 2,266 3,266
92 MIRROR-BACKUP INACTIVE STOPPED HARDDOWN 2,266 3,266
General Disk Information:
Device Type........... 3 Device Subtype........... 53
Primary Drive Type.... Mirror Drive Type........
Physical Record Size.. 4096 Priority................. 220
Library File..........
Program File.......... $SYSTEM.SYS00.TSYSDP2
Protection............ MIRRORED
Hardware Information:
Path Location Power Physical Status
(group,module,slot)
PRIMARY EXTERNAL DUAL PRESENT
MIRROR EXTERNAL NONE ABSENT
Total Errors = 0 Total Warnings = 0
34-> STATUS $DATA01
STORAGE - Status DISK \SHARK.$DATA01
LDev Primary Backup Mirror MirrorBackup Primary Backup
PID PID
63 *STARTED STARTED *STARTED STARTED 0,267 1,266
47-> STATUS DISK $DATA02-M
STORAGE - Status DISK \SHARK.$DATA02-M
LDev Path PathStatus State SubState Primary Backup
PID PID
62 MIRROR INACTIVE STOPPED HARDDOWN 0,268 1,265