Hitachi GR2000 Network Router User Manual


 
4.2.6 Maximum Number of Interfaces and Multihome Subnets
4.2.6.1 Maximum Number of Interfaces
The number of units to which IP addresses are given is called the number of
interfaces. See Table 4-34 for the maximum number of interfaces. The values shown
are for the communication interfaces and hence do not count the RM Ethernet
connection interface for the router management. In addition, the maximum number
ofinterfacesassumesstaticrouting.ForthecaseofdynamicroutingsuchasRIPor
OSPF, the effective number of interfaces largely depends on the route calculation
performance of the subject protocol.
Router Model
M
aximum Number of VCs
Per Line Per NIF Per Interface Per RP Per Router
GR2000-2S 2,048 2,048 64 4,096 4,096
GR2000-4S 2,048 2,048 64 4,096 4,096
GR2000-6H 2,048 2,048 64 4,096 4,096
GR2000-10H 2,048 2,048 64 4,096 4,096
GR2000-20H 2,048 2,048 64 4,096 4,096