Restrictions applicable to NWJ1-8U circuit multiplex connections
When mounting NWJ1-8U in the device and setting the PRI circuit, there are limit
the number of circuit interfaces and multiplexed time slots. NWJ1-8U restriction
are given in Table 4-80
Table 4-80 NWJ1-8U connection restrictions
Line
number
Interface
Time slots start
number
Posible Time
slots
The number
time slots
0 High speed digital (1.5M) (leased line)/
High speed digital (1.5M) (ISDN)
TS1toTS24 1to24 1to24
1 High speed digital (1.5M) (leased line)/
High speed digital (1.5M) (ISDN)
TS1toTS24 1to24 1to24
2 High speed digital (1.5M) (leased line)/
High speed digital (1.5M) (ISDN)
TS1toTS24 1to24 1to24
3 High speed digital (1.5M) (leased line)/
High speed digital (1.5M) (ISDN)
TS1toTS24 1to24 1to24
4 High speed digital (1.5M) (leased line) TS1 to TS24 1 to 24 (It is possible
define the tim
5 High speed digital (1.5M) (leased line) TS1 to TS24 1 to 24