Honeywell 1202g Barcode Reader User Manual


 
7 - 4
Concatenation Timeout
When searching for bar codes during concatenation, you may wish to set a delay used to find the next bar code. Set
the length (in milliseconds) for this delay by scanning the following bar code, then setting the timeout (from 1-65535
milliseconds) by scanning digits from the Programming Chart, then scanning Save. Default = 750.
Codabar Redundancy
If you are encountering errors when reading Codabar bar codes, you may want to adjust the redundancy count. Redun-
dancy adjusts the number of times a bar code is decoded before transmission, which may reduce the number of errors.
Note that the higher the redundancy count, the longer it will take to decode the bar code. To adjust the redundancy, scan
the following Codabar Redundancy bar code, then scan a redundancy count between 0 and 10 on the Programming Chart
inside the back cover of this manual. Then scan the Save bar code. Default = 0.
Codabar Message Length
Scan the following bar codes to change the message length. Refer to Message Length Description (page 7-1) for addi-
tional information. Minimum and Maximum lengths = 1-80. Minimum Default = 3, Maximum Default = 80.
Concatenation Timeout
Codabar Redundancy
Minimum Message Length
Maximum Message Length