Honeywell 1202g Barcode Reader User Manual


 
7 - 44
When Check Character is set to Validate Type 10/11, but Don’t Transmit, the unit will only read MSI bar codes printed
with the specified type check character(s), but will not transmit the check character(s) with the scanned data.
MSI Redundancy
If you are encountering errors when reading MSI bar codes, you may want to adjust the redundancy count. Redundancy
adjusts the number of times a bar code is decoded before transmission, which may reduce the number of errors. Note that
the higher the redundancy count, the longer it will take to decode the bar code. To adjust the redundancy, scan the MSI
Redundancy bar code below, then scan a redundancy count between 0 and 10 on the Programming Chart inside the back
cover of this manual. Then scan the Save bar code. Default = 0.
* Validate Type 10, but Don’t
Transmit
Validate Type 10 and Transmit
Validate 2 Type 10 Characters,
but Don’t Transmit
Validate 2 Type 10 Characters
and Transmit
Validate Type 10 then Type 11
Character, but Don’t Transmit
Validate Type 10 then
Type 11 Character and Transmit
Disable MSI Check Characters
MSI Redundancy