10 - 14
Object Detection Laser Timeout Out-of-
Stand
(Range 1 - 65525) *5000 ms
AOSODT##### 4-11
*Object Detection Distance - Short In-
Stand
AISRNG2 4-11
Object Detection Distance - Long In-Stand AISRNG1 4-11
Object Detection Distance - Short Out-of-
Stand
AOSRNG2 4-11
*Object Detection Distance - Long Out-of-
Stand
AOSRNG1 4-11
Character Activation Mode *Off HSTCEN0 4-11
On HSTCEN1 4-12
Activation Character HSTACH## 4-12
Do Not End Character Activation After
Good Read
HSTCGD0 4-12
*End Character Activation After Good
Read
HSTCGD1 4-12
Character Activation Laser Timeout
(Range 1 - 65525) *5000 ms
HSTCDT##### 4-12
Character Deactivation Mode *Off HSTDEN0 4-12
On HSTDEN1 4-13
Deactivation Character HSTDCH## 4-13
Reread Delay Short (500 ms) DLYRRD500 4-13
*Medium (750 ms) DLYRRD750 4-13
Long (1000 ms) DLYRRD1000 4-13
Extra Long (2000 ms) DLYRRD2000 4-13
User-Specified Reread Delay Range 0 - 30,000 ms DLYRRD##### 4-13
Output Sequence Editor Enter Sequence SEQBLK 4-16
Default Sequence SEQDFT 4-16
Sequence Timeout (Range 1 - 65535) *5000 ms SEQDLY##### 4-16
Sequence Match Beeper *On SEQBEP1 4-16
Off SEQBEP0 4-16
Partial Sequence Transmit Partial Sequence SEQTTS1 4-16
*Discard Partial Sequence SEQTTS0 4-17
Require Output Sequence Required SEQ_EN2 4-17
On/Not Required SEQ_EN1 4-17
*Off SEQ_EN0 4-17
No Read On SHWNRD1 4-17
*Off SHWNRD0 4-17
Prefix/Suffix Selections
Add CR Suffix to All Symbologies VSUFCR 5-2
Prefix Add Prefix PREBK2## 5-2
Clear One Prefix PRECL2 5-2
Clear All Prefixes PRECA2 5-2
Selection
Setting
* Indicates default
Serial Command
# Indicates a numeric entry
Page