Honeywell 1202g Barcode Reader User Manual


 
2 - 1
2
Programming the Interface
Introduction
This chapter describes how to program your system for the desired interface.
Programming the Interface - Plug and Play
Plug and Play bar codes provide instant scanner set up for commonly used interfaces.
Note: After you scan one of the codes, power cycle the host terminal to have the interface in effect.
Keyboard Wedge
If you want your system programmed for an IBM PC AT and compatibles keyboard wedge interface with a USA keyboard,
scan the bar code below. Keyboard wedge is the default interface.
Note: The following bar code also programs a carriage return (CR) suffix.
IBM PS2 Keyboard
The following bar code programs you scanner for an IBM PS2 keyboard wedge interface with a USA keyboard.
Note: The following bar code also programs a carriage return (CR) suffix.
RS232 Serial Port
The RS232 Interface bar code is used when connecting to the serial port of a PC or terminal. The following RS232 Inter-
face bar code also programs a carriage return (CR) and a line feed (LF) suffix, baud rate, and data format as indicated
below.
RS485
Scan one of the following “Plug and Play” codes to program the scanner for an IBM POS terminal interface.
Note: After scanning one of these codes, you must power cycle the cash register.
Option Setting
Baud Rate 115,200 bps
Data Format 8 data bits, no parity bit, 1 stop bit
IBM PC AT and Compatibles with CR Suffix
IBM PS2 with CR Suffix
RS232 Interface
IBM Port 5B Interface