Honeywell 1202g Barcode Reader User Manual


 
4 - 9
CodeGate
When CodeGate is On, the button is used to allow decoded data to be transmitted to the host system. The scanner
remains on, scanning and decoding bar codes, but the bar code data is not transmitted until the button is pressed. When
CodeGate is Off, bar code data is transmitted when it is decoded. Default = CodeGate Off in-Stand, CodeGate On Out-of-
Stand.
Button Function
Note: Button Function applies only to the Voyager 1202. It is not supported in the Voyager 1200.
When Button Function is set to On, press and hold the button for 7 seconds to change the CodeGate setting from Code-
Gate Off Out-of-Stand to CodeGate On Out-of-Stand. When the scanner is power cycled, the CodeGate function reverts
to the saved CodeGate setting. When Button Function is set to Off, holding the button down for 7 seconds shuts down the
scanner. Default = Off.
Object Detection Mode
Object Detection Mode uses an LED to detect when an object is in the scanner’s field of view. When an object is detected,
the laser turns on and the scanner attempts to scan the bar code. Default = Object Detection Mode On In-Stand.
* CodeGate Off
In-Stand
CodeGate On
In-Stand
CodeGate Off
Out-of-Stand
* CodeGate On
Out-of-Stand
* Button Function Off
Button Function On
Object Detection Mode Off
In-Stand