Note: See Chapter 7, “Parts listing, BladeCenter T Type 8720 and 8730,” on page 107 to determine which
components should be replaced by a field service technician.
Message Action
Received an [xxx] alert from an
unsupported ISMP type xxxx, via the
interconnect network
Ensure that all blade servers in the blade center are supported by
the management module.
KVM error message
Note: See Chapter 7, “Parts listing, BladeCenter T Type 8720 and 8730,” on page 107 to determine which
components should be replaced by a field service technician.
Message Action
Error encountered switching KVM owner,
see system error log
1. Reseat the blade server.
2. Reseat the KVM module.
3. Reflash the blade server H8 firmware.
4. Replace the blade server.
5. Replace the KVM module.
6. Replace the midplane.
Switch error messages
Note: See Chapter 7, “Parts listing, BladeCenter T Type 8720 and 8730,” on page 107 to determine which
components should be replaced by a field service technician.
Message Action
Switch fault x
1. Reseat switch x.
2. Replace switch x.
Switch module x was removed Information only. Take action as required.
Switch module x was installed Information only. Take action as required.
Switch module x was powered on Information only. Take action as required.
Switch module x was powered on Information only. Take action as required.
Switch System running nonredundant
switch modules
Information only. Take action as required.
Switch module%d IP configuration was
changed
Information only. Take action as required.
ENET [X] DHCP HSTN=X, DN=X, IP @=
XXX.XXX.XXX.XXXGW @=
XXXX.XXX.XXX.XXX, SN=
XXX,XXX,XXX,XXX, DNS1@=
XXX.XXX.XXX.XXX
Ethernet configuration information. Take action as required.
ENET [X] IP Cfg:HstName= XXXX, IP@=
XXX.XXX.XXX.XXX ,GW@=
XXX.XXX.XXX.XXX, NetMsk=
XXX.XXX.XXX.XXX Switch module x was
installed
Ethernet configuration information. Take action as required.
LAN: Ethernet [x] interface is no longer
active
Check cables to switch.
102 BladeCenter T Type 8720 and 8730: Hardware Maintenance Manual and Troubleshooting Guide