IBM Type 8730 Server User Manual


 
Features and specifications for the BladeCenter T Type 8730 unit
The following table provides a summary of the features and specifications of the
BladeCenter T Type 8730 unit.
Table 2. BladeCenter T Type 8730 features and specifications
Media tray (on front):
v DVD/CD-RW drive: slim IDE
v Two Universal Serial Bus (USB) v2.0
full speed ports
v System-status panel
Module
bays (on front):
v Eight hot-swap blade bays
v Four hot-swap power-module bays
v Two hot-swap management module
bays
Module bays (on rear):
v Four hot-swap I/O module bays
v Four hot-swap blower bays
v One hot-swap KVM (keyboard, video,
mouse) module
v One hot-swap LAN module
Power
modules:
v Standard: Two 1300-watt or greater
220-volt (200-240 V ac) hot-swap
power modules
Power modules 1 and 2 supply
power to:
- Blade bays 1 through 4
- Management modules 1 and 2
- I/O modules 1 and 2
- Media tray
- All KVM, LAN, and alarm
interfaces
- All four blower modules
Power modules 1 and 2 provide
redundancy to each other
v
Maximum: Four 1300-watt or greater
220-volt (200-240 V ac) hot-swap
power modules
Power modules 3 and 4 supply
power to:
- Blade bays 5 through 8
- I/O modules 3 and 4
Power modules 3 and 4 provide
redundancy to each other
Blowers are powered by all four
power modules
LAN module:
v Two 10/100 Mb Ethernet remote
management connections
v One DSUB 15P alarm connector
KVM
module:
v Video port (analog)
v PS/2 keyboard port
v PS/2 mouse port
v System-status panel
I/O modules:
v Standard: None
v Maximum: Four
Two hot-swap 1 Gb Ethernet
four-port switch modules
Two hot-swap switch modules of
another network-communication
standard, such as Fibre Channel
Management
module:
v Standard: One hot-swap management
module providing system-management
functions for the BladeCenter T unit
v Maximum: Two hot-swap management
modules (one active, one redundant)
Redundant
cooling:
Four variable-speed hot-swap blowers
Front bezel with changeable filter
Upgradeable microcode:
v management module firmware
v I/O-module firmware (not all I/O module
types)
v Blade server service processor firmware
(BIOS, service processor)
Size
(8 U):
v Height: 349.25 mm (13.75 in. or 8 U)
v Depth: 508 mm (20 in.) from front of
chassis to rear I/O connector plane
Maximum depth: 600 mm (23.62 in.)
including bezel, handles, and cable
bend radius.
v Width: 442 mm (17.4 in.)
v Weight:
Fully configured with modules and
blade servers: Approx. 100.2 kg (221
lb)
Fully configured without blade
servers: Approx. 61.7 kg (136 lb)
Security
features:
v Login password for remote connection
v Secure Shell (SSH) for command-line
interface
v Secure socket layer (SSL) security for
remote Web management access
Predictive
Failure Analysis (PFA) alerts:
v Blowers
v Blade-dependent features
v Power supplies
Declared acoustical noise emission levels
for normal operations:
v Sound-power levels (upper-limit):7.8 bels
v Sound-pressure levels (average), for four
one-meter bystander positions: 63 dBA
The
noise emission levels stated are the
declared upper limit sound-power levels, in
bels, for a random sample of machines. All
measurements made in accordance with ISO
7779 and reported in conformance with ISO
9296.
Environment:
v Air temperature:
BladeCenter T on: 10° to 35°C (50° to
95°F). Altitude: 0 to 914 m (2998.69 ft).
BladeCenter T on: 10° to 32°C (50° to
89.6°F). Altitude: 914 m to 2134 m
(2998.69 ft to 7000 ft).
BladeCenter T off: -40° to 60° C (-40° to
140°).
v Humidity:
Server on: 8% to 80%
Server off: 8% to 80%
Electrical
input:
v Sine-wave input (50 or 60 Hz single-phase)
required
v Input voltage:
Minimum: 200 V ac
Maximum: 240 V ac
v
Input current:
Chassis: 18 amp maximum @ 208 V ac
Single power-supply feed: 9 amp
maximum
v
Input connector type: Four (4) C13 inputs,
rated at 8 amps each
Heat
output:
v Input kilovolt-amperes (kVA) approx.
Minimum configuration: 0.2 kVA
Maximum configuration: 3.5 kVA
v
BTU output
Ship configuration:
673 Btu/hour (197 watts)
Full configuration:
11900 Btu/hour (3490 watts)
Chapter 1. General information 7