Chapter 4 — Enabling and Configuring Symbologies
SR60 Scanner Programmer’s Reference Manual 119
Label Length Format
The next two sections let you set the Standard 2 of 5/IATA label
length format to either Variable Length or Fixed Length format.
Variable Length Format
You can set the Standard 2 of 5/IATA symbology to read Variable
Length Format.
To set Standard 2 of 5/IATA symbology to read Variable Length Format
1 Identify the minimum length setting you want to make. The
selectable range is 02 to 50 characters.
2 Scan the SET bar code.
3 Scan the Enable Variable Length Format bar code.
4 Scan the Set Minimum Label Length bar code.
5 Using the Digits bar codes on page 122, scan the digits to set
the minimum label length you identified in Step 1.
6 Scan the END bar code.
END ------------------------------------------
Note: For this symbology, the scanner decodes up to 50
characters, but the actual length read varies depending upon the
interface type, bar code physical size, and print quality.
Note: To set a label length less than ten, you must scan a zero
digit first and then the length digit (such as 04, 06, or 08).
Variable Length Format
SET ------------------------------------------