Intermec SR60 Scanner User Manual


 
Chapter 4 — Enabling and Configuring Symbologies
SR60 Scanner Programmer’s Reference Manual 73
Minimum Label Length
The following procedure explains how to set the Code 39
Minimum Label Length.
To set Code 39 Minimum Label Length
1 Identify the minimum label length setting you want to make.
The selectable range is 00 to 48 characters.
2 Scan the SET bar code.
Transmit ---------
Code 39 Full ASCII
Enable ---------
Disable ---------
END ------------------------------------------
Note: For this symbology, the scanner decodes up to 48
characters, but the actual length read varies depending upon
interface type, bar code physical size, and print quality. Code
39 bar codes containing one or more full ASCII characters can
also limit the amount of characters that are decoded; in these
circumstances, the scanner decodes at least 24 data characters.