Chapter 4 — Enabling and Configuring Symbologies
120 SR60 Scanner Programmer’s Reference Manual
Fixed Length Format
All interfaces that are shipped with the standard factory
configuration are set to read variable length labels. If you switch
from variable length to fixed length format, the default fixed
labels are 14 characters and 8 digits.
To change the defaults for the Standard 2 of 5/IATA symbology
1 Identify the fixed length settings you want to make.
2 Scan the SET bar code on page 121.
3 Scan the Enable Fixed Length Format bar code .
4 Scan the Set First Fixed Length bar code.
5 Using the Digits bar codes on page 122, scan the digits to set
the first fixed label length you identified in Step 1.
• If you need to set a second fixed length, continue with
Step 6.
• If you do not need to set a second fixed length, scan the
No Second Fixed Length bar code and skip to Step 8.
6 Scan the Set Second Fixed Length bar code.
7 Using the Digits bar codes on page 122, scan the digits to set
the second fixed label length you identified in Step 1.
Enable Variable Length
Format ---------
Set Minimum Label
Length ---------
END ------------------------------------------
Note: To set a label length less than ten, you must scan a zero
digit first and then the length digit (such as 04, 06, or 08).