Intermec SR60 Scanner User Manual


 
Chapter 4 — Enabling and Configuring Symbologies
84 SR60 Scanner Programmer’s Reference Manual
The Set First Fixed Length bar code on page 88 instructs
the scanner that the next two programming labels scanned
will define the first fixed label length. This setting can be
any even number of characters between 02 and 50
characters.
The Set Second Fixed Length bar code on page 88
instructs the scanner that the next two programming
labels scanned will define the second fixed label length.
This setting can be any even number of characters between
02 and 50 characters.
The No Second Fixed Length bar code on page 88
configures the scanner to recognize only the first fixed
length.
Read Verification
Read Verification is the number of times the scanner is required
to read the bar code data before sending the label data to the host.
Configuring the Interleaved 2 of 5 Options
Scan the following bar codes to configure the Interleaved 2 of 5
symbology options.
Note: For this symbology, the scanner decodes up to 50
characters, but the actual length read varies depending
upon the interface type, bar code physical size, and print
quality.
Check Digit
SET ------------------------------------------
Don’t Calculate ---------