Juniper Networks J6350 Network Router User Manual


 
If Crypto Module appears in the output, the Crypto Accelerator Module is installed
correctly.
Replacing Air Filters on J2350 Routers
The cooling fans on J2350 routers draw air through vents along the left side of the
chassis and exhaust it through vents on the right side of the chassis. For more
information, see J2320 and J2350 Cooling System on page 25.
On J2350 routers that comply with Network Equipment Building System (NEBS)
criteria, the air intake grid contains a filter. To verify that the system is a
NEBS-compliant system, run the show chassis hardware command. A NEBS-compliant
system displays the term NEBS in the output.
We recommend changing the filter every 6 months. However, the optimal filter
replacement interval can vary depending on the environment where the router is
located. If temperature alarms appear, inspect the air filter.
To replace the air filter:
1. Loosen the filter tray thumbscrew at the rear of the J2350 chassis.
2. Hold the screw firmly and pull it away from the chassis until you have pulled the
attached filter tray out of the chassis (see Figure 101 on page 205).
Figure 101: Removing the Air Filter Tray
3. Hook-and-loop fasteners on the base of the filter tray hold the air filter inside
the tray. Grasp the air filter with your fingers and gently pull it away from the
filter tray.
4. Set the old air filter aside.
5. Place the new filter so that its edge aligns with the first hook-and-loop fastener
as shown Figure 102 on page 206.
Replacing Air Filters on J2350 Routers 205
Chapter 10: Replacing Hardware Components