Kodak A-61092 Scanner User Manual


 
A-61092 September 1999 4-5
Function code listing
Following is a listing of the function codes and descriptions.
Code Function Code Name Description
F01 Select Mode Allows you to select one of the predefined application
modes. Enter a value from 1 to 18 and press Enter.
F02 Restore Mode Allows you to restore the current application mode to its
default status, provided mode overrides are not saved.
F04 Counting Only
Allows you to count the number of documents entering
the scanner without scanning. Enter 1 to turn Counting
Only on, or 0 to turn Counting Only off and press Enter.
F05 Accessory Status Displays the current status of each accessory installed.
Press the Down arrow to view the status of the next
accessory, or press the Up arrow to view the status of the
previous accessory.
F06 Terminate Batch Allows you to prematurely end a batch.
F07 Level 0 Allows you to define the next document scanned as a
Level 0 document.
F08 Last Image Address Allows you to display the image address of the last
document scanned.
F09 Total Document Count
Allows you to display the total number of documents that
entered the feeder (Level 3, Level 2, Level 1 or Level 0).
Press 0 to reset the counter and then press Enter.
F10 Level 0 Count Allows you to display the total number of documents that
have entered the feeder as Level 0 documents. Press 0 to
reset the counter and then press Enter.
F11 Level 1 Count Allows you to display the total number of documents that
have entered the feeder as Level 1 documents. Press 0 to
reset the counter and then press Enter.
F12 Level 2 Count Allows you to display the total number of documents that
have entered the feeder as Level 2 documents. Press 0 to
reset the counter and then press Enter.
F13 Level 3 Count Allows you to display the total number of documents that
have entered the feeder as Level 3 documents. Press 0 to
reset the counter and then press Enter.
F14 Reset Level Counts
Allows you to reset all the level counters (Level 0, Level 1,
Level 2, and Level 3) to 0.
F15 Alarm Volume Allows you to adjust the volume of the alarm. Press the
Up arrow to increase the volume or press the Down
arrow to decrease the volume, then press Enter.
F16 Alarm Tone Allows you to adjust the pitch of the alarm tone. Press the
Up arrow to increase the pitch or press the Down arrow
to decrease the pitch, then press Enter.