A-61092 September 1999 5-1
5 Maintenance
Cleaning tasks
To keep your scanner in good operating condition, the following tasks
should be performed:
• Cleaning the imaging guides (daily)
• Cleaning the feed and separator roller (semi-automatic feeder)
(daily)
• Cleaning the feeder module and separator roller (automatic feeder)
(daily)
• Cleaning the paper path (daily)
• Vacuuming inside the scanner (daily)
• Cleaning the exposure lamp housings (weekly)
• Cleaning the cabinet (weekly)
• Cleaning the air filter (monthly)
For additional maintenance and feeder adjustment information, see
Kodak publication A-61604. This publication is part of the Maintenance
and Feeder Adjustment procedure video; Catalog Number 828 5306.
Cleaning materials
Materials needed to perform maintenance procedures are:
• A mild cleaning agent
• A quality lens cleaner
• A soft, clean, lint-free cloth
• A soft-bristled cleaning brush
• A vacuum cleaner
• Staticide Wipes
• Roller Cleaning Pads
• Paper Path Cleaner
IMPORTANT:
Do not use any unauthorized commercial cleaning
solvent in any of the cleaning procedures.
Replacement parts
Consumable parts that can be replaced by the customer include:
• Air filter
• Exposure lamps
• Imaging guides
• Automatic Document Feeder Module
• Automatic Document Feeder Separator Roller
Instructions on how to replace these parts are included later in this
chapter.