5-2 A-61092 September 1999
Daily maintenance
procedures
Maintenance procedures that should be performed daily include
cleaning the imaging guides, the feed and separator rollers, the paper
path and vacuuming inside the scanner.
Cleaning the imaging
guides
To clean the imaging guides, follow the steps below:
IMPORTANT:
Do not use any abrasive materials when cleaning the
imaging guides. This includes abrasive cleansers,
commercial solvents, paper towels, or coarse cloths.
1. Open the right-side access door.
NOTE: The illustration below shows the rear view of the scanner.
Upper lamp
housing assembly
Upper imaging guide
Lower image guide
Lower lamp housing
assembly
Right-side access door
Upper imaging guide
Lower imaging guide
2. Locate and grasp the end of the upper imaging guide. Carefully
slide the imaging guide out of its track.
3. Locate and grasp the end of the lower imaging guide. Carefully
slide the imaging guide out of its track.