Kodak A-61092 Scanner User Manual


 
5-8 A-61092 September 1999
Cleaning the feeder/
horizontal transport area
The sensors in the feeder/horizontal transport area are located under
the horizontal plate, behind the feed/separator rollers, near the reflector
strips.
1. Open the front cover.
2. Raise the horizontal plate.
3. Vacuum the area underneath the horizontal plate.
4. Remove the lower belt module.
5. Vacuum under the module and wipe with a clean, damp cloth.
6. Replace the lower belt module.
7. Lower the horizontal plate back into place.
8. Close the front cover.
Cleaning the lower roller
housing assembly area
To clean the lower roller housing assembly area, follow the steps
below:
1. Open the top cover.
2. Open the right-side access door.
3. Remove the imaging guides (not shown in illustration).
IMPORTANT:
Use care when handling the imaging guides. Hold
the imaging guides by the green handles only.
Vertical baffle handle
Baffle plate
Lower roller
housing
assembly
Screen
Lower roller
housing assembly
4. Grasp the vertical baffle handle, push it in and turn it
counterclockwise until the baffle plate unlatches. Pull the baffle
plate down until it stops, this unlocks the lower roller housing
assembly.