Kodak A-61092 Scanner User Manual


 
5-10 A-61092 September 1999
Weekly maintenance
procedures
Maintenance procedures that should be performed weekly include
cleaning the exposure lamp housings and cleaning the cabinet.
Cleaning the exposure
lamp housings
The upper and lower lamp housings should be cleaned.
1. Open the right-side access door.
2. Remove the upper and lower imaging guides (between the upper
and lower exposure lamp housings — not shown in this illustration).
IMPORTANT:
Use care when handling the imaging guides. Hold
the imaging guides by the green handles only.
Upper lamp housing
Area to
vacuum
Lower lamp housing
2. Remove the lower lamp housing.
3. Vacuum the housing.
4. Replace the lower lamp housing.
5. Remove the upper lamp housing.
6. Vacuum the housing.
7. Replace the upper lamp housing.
8. Replace the upper and lower imaging guides.
9. Close the right-side access door.
Cleaning the cabinet
Clean the exterior of the scanner, the feed shelf, and the hopper area
with a soft cloth. Remove any fingerprints, stains, or stubborn dirt with a
cloth dampened with water or a mild cleaning agent.