A-61092 September 1999 7-5
The imaging guide
area
To clear the imaging guide area (Area B):
1. Open the right-side access door.
Upper lamp
housing
assembly
Lower imaging
guide
Upper imaging
guide
2. Locate and remove only the upper imaging guide.
IMPORTANT:
Use care when handling the imaging guides. Hold
the imaging guides by the green handles only.
3. Locate and remove the upper lamp housing assembly.
4. Remove any documents or document pieces.
5. Reinsert the upper lamp housing assembly.
6. Reinsert the upper imaging guide.
7. Close the right-side access door.
NOTE: It may also be helpful to remove the lower lamp housing