Message
number Component Test State Description Action
Media is not
detected.
1. Clean the tape drive, using the
appropriate cleaning media, and insert
new media.
2. Run the test again.
3. Clear the error log.
4. Make sure that the drive firmware is at
the latest level. For the latest level of
drive firmware and software for tape
drives and libraries, go to
http://www.ibm.com/support/
docview.wss?uid=psg1TAPE-FILES.
5. Run the test again.
6. Replace the tape drive.
7. If the failure remains, collect the data
from the DSA event log and send it to
IBM Service. For information about
contacting and sending data to IBM
Service, go to http://www.ibm.com/
support/
docview.wss?uid=psg1SERVCALL.
Failed Media error.
1. Clean the tape drive, using the
appropriate cleaning media, and insert
new media.
2. Run the test again.
3. Make sure that the drive firmware is at
the latest level. For the latest level of
drive firmware and software for tape
drives and libraries, go to
http://www.ibm.com/support/
docview.wss?uid=psg1TAPE-FILES.
4. Run the test again.
5. Replace the tape drive.
6. If the failure remains, collect the data
from the DSA event log and send it to
IBM Service. For information about
contacting and sending data to IBM
Service, go to http://www.ibm.com/
support/
docview.wss?uid=psg1SERVCALL.