Madrigal Imaging MP-9 Projector User Manual


 
Notes: 1. Blanking can be increased with left and right blanking controls
2. Retrace fixed as Short in ranges 4560 kHz and 100152 kHz
despite user setting
3. Defl. retrace time must be less than the max. blanking duration
4. Horizontal blanking duration of the source must be more than
the max. blanking duration of the projector to avoid cutting off
the left or right edge of the source image.
5. Max. Blanking duration of the projector must be compatible with
all known sources (at the specific source frequency).
6. Max. Blanking duration of the projector restricted to 1.5µs for
operation in the range 120 kHz152kHz.
High Voltage
34.9 KV regulated to better than ±1%
Power
Requirements
90 VAC to 264 VAC universal input
Line Frequency: 50 to 60 Hz nominal
Power: 650 watts maximum
Power factor corrected
Inputs
Built-in RGBHV interface. Optional interface modules install in
interface slot
Built-in RS-232 for computer control, with loop-thru for connection
of multiple projectors
HDTV compatible with optional interface module
Optional Source
Expansion
The Signal Switcher allows use of nine additional input modules. Up
to nine switchers can be connected
Maximum Number of Inputs: 78
Control Features
Multi-language software (user selectable)
Menu driven interface with on-screen help
Built-in set up tutorials
Auto power up after power interruption
Six built-in test patterns
Internal frequency generator
Programmable events and real time clock
Servicing
Modular design for ease of servicing
Most service adjustments are made using the keypad
SPECIFICATIONS
5.3