2.2 Mounting
If the CDM-570/570L is to be mounted in a rack, ensure that there is adequate clearance
for ventilation, particularly at the sides. In rack systems where there is high heat
dissipation, forced air cooling must be provided by top or bottom mounted fans or
blowers. Under no circumstance should the highest internal rack temperature be allowed
to exceed 50°C (122°F).
IMPORTANT
The CDM-570/570L CANNOT have rack slides mounted to the side of
the chassis. Two cooling fans are mounted on the right-hand side of the
unit. However, Comtech EF Data recommends that an alternate method of
support within the rack be employed, such as rack shelves. If there is any
doubt, please consult the Comtech EF Data Customer Support department.
2.2.1 Optional Rear-Mounting Installation Bracket
Install optional installation bracket (Figure 2-1) using mounting kit, KT/6228-2.
Table 2-1. Optional Mounting Kit , KT/6228-2
Quantity Part Number Description
2
FP/6138-1 Bracket, Rear Support
4 HW/10-32x1/2RK Bolt, #10 Rack
2 HW/10-32HEXNUT Nut, #10 Hex
4 HW/10-32FLT Washer, #10 Flat
2 HW/10-32SPLIT Washer, #10 Split
2 HW/10-32SHLDR Screw, Shoulder #10
The tools required for this installation are a medium Phillips screwdriver, and a
5/32-inch SAE Allen Wrench.
Refer to the following Figure, then install the Modem rear support brackets as follows:
a) Install the rear support brackets onto the mounting rail of the rack. Fasten with the
bracket bolts.
b) Mount the modem into the equipment rack ensuring that the socket heads engage into
the modem slots of the rear support brackets.
c) Fasten the provided #10 shoulder head screws to the rear-side mounting slots on
either side of the chassis modem and secure with #10 flat washers, #10 split washers,
and #10 hex nuts.