Mocomtech CDM-570L Modem User Manual


 
CDM-570/570L Satellite Modem with Optional IP Module Revision 4
IP Module - CLI and Telnet Operation MN/CDM570L.IOM
17.2.9.4 Database Operations Page
Database Operations Page is activated from Operations and Maintenance Page.
The Database Operations option allows the user to view, save, or erase an existing user
configuration of the IP Module. An IP Module uses these types of configuration files to
initialize itself on power-up.
The User Configuration File allows a User to over-write the values defined in the Factory
Configuration file. This allows full customization of a IP Module without erasing a set of
parameters defined from the factory. The User configuration file can also be retrieved or
overwritten via FTP by specifying the filename ‘param1’.
The Administrative Database Operations Page contains the following options/fields:
Menu Options/Fields Entry Description
Restore Factory Default
R
Restores the
IP Module settings to “safe” values as
defined by the factory.
Load Parameters from
permanent storage
P
This option overwrites the current configuration of the
IP
M
odule with the configuration last saved to permanent
storage. It allows the user to perform an “Undo” type
operation if the
IP Module is put into an undesirable
state by the user.
Save Parameters
S
This option allows a user to save the current
configuration of the
IP Module to permanent storage.
This configuration will be restored on each successive
power cycle.
Exit
X
This option allows a user to exit the current menu and
return to its parent menu.