Mocomtech CDM-570L Modem User Manual


 
CDM-570/570L Satellite Modem with Optional IP Module Revision 4
Front Panel Operation MN/CDM570L.IOM
6–8
changed using the ▲▼ arrow keys. The user should then press ENTER. The
valid range of addresses is from 1 to 9999.
(CONFIG, REM, SERIAL, BAUD RATE)
If the user selects Baud Rate, the user is presented with the following menu:
Edit the baud rate of the remote control bus, connected locally to the M&C
computer. The value is changed using the
arrow keys. The user should then
press ENTER. Values of 2400, 4800, 9600,19200, 38400 and 57600 baud are
possible.
Note that the asynchronous character format is FIXED at 8 data bits, 1 stop bit,
no parity (8-N-1).
6.5.2 (CONFIG, REMOTE) ETHERNET
If Ethernet is selected the following sub menu is displayed:
(CONFIG, REMOTE, ETHERNET) GATEWAY
If Gateway is selected the following sub-menu is displayed:
Edit the IP Gateway Address for the Ethernet M&C port for this unit. This is
accomplished by selecting the digit to be edited, using the arrow keys. The
value of the digit is then changed using the
arrow keys. The user should
then press ENTER.
(CONFIG, REMOTE, ETHERNET) ADDRESS
If Address is selected the following sub-menu is displayed:
Edit the IP Address and Range for the Ethernet M&C port for this unit. This is
accomplished by selecting the digit to be edited, using the
arrow keys. The
value of the digit is then changed using the
arrow keys. The user should
then press ENTER.
Local M&C Bus Baud Rate:
19200 Baud ( ,ENTER)
Ethernet IP Gateway:
192.168.001.002 ( , )
Ethernet Config: Gateway
Address MAC SNMP ( )
Ether IP Address/Range:
192.168.001.002/24 ( , )