CDM-570/570L Satellite Modem with Optional IP Module Revision 4
Front Panel Operation MN/CDM570L.IOM
6–8
changed using the ▲▼ arrow keys. The user should then press ENTER. The
valid range of addresses is from 1 to 9999.
(CONFIG, REM, SERIAL, BAUD RATE)
If the user selects Baud Rate, the user is presented with the following menu:
Edit the baud rate of the remote control bus, connected locally to the M&C
computer. The value is changed using the
▲ ▼ arrow keys. The user should then
press ENTER. Values of 2400, 4800, 9600,19200, 38400 and 57600 baud are
possible.
Note that the asynchronous character format is FIXED at 8 data bits, 1 stop bit,
no parity (8-N-1).
6.5.2 (CONFIG, REMOTE) ETHERNET
If Ethernet is selected the following sub menu is displayed:
(CONFIG, REMOTE, ETHERNET) GATEWAY
If Gateway is selected the following sub-menu is displayed:
Edit the IP Gateway Address for the Ethernet M&C port for this unit. This is
accomplished by selecting the digit to be edited, using the ◄ ► arrow keys. The
value of the digit is then changed using the
▲ ▼ arrow keys. The user should
then press ENTER.
(CONFIG, REMOTE, ETHERNET) ADDRESS
If Address is selected the following sub-menu is displayed:
Edit the IP Address and Range for the Ethernet M&C port for this unit. This is
accomplished by selecting the digit to be edited, using the
◄ ► arrow keys. The
value of the digit is then changed using the
▲ ▼ arrow keys. The user should
then press ENTER.
Local M&C Bus Baud Rate:
19200 Baud (▲ ▼,ENTER)
Ethernet IP Gateway:
192.168.001.002 (◄ ►,▲ ▼)
Ethernet Config: Gateway
Address MAC SNMP (◄ ►)
Ether IP Address/Range:
192.168.001.002/24 (◄ ►,▲ ▼)